How to Remove the Ion Source from an Agilent GC/MS | Source Maintenance Tutorial
Before cleaning or servicing a GC/MS ion source, the source first has to be removed correctly. In this video, I show how I remove the ion source from an Agilent GC/MS for maintenance. I cover: • Accessing the analyzer after the MSD has been vented • Opening the analyzer • Disconnecting the source assembly • Removing the ion source • Handling the source carefully before cleaning or service Ion source removal is a routine part of GC/MS maintenance, but the sequence matters. Und
Vineta Mills
3 hours ago1 min read


How to Disassemble an Agilent EI Extractor Source | GC/MS Source Cleaning Prep
Before cleaning a GC/MS ion source, it has to be disassembled carefully and kept organized. In this video, I show how I disassemble an Agilent EI extractor source before cleaning. I cover: • Removing the source components step by step • Disconnecting the filament and electrical connections • Separating the source body and lens components • Removing the smaller screws and source parts • Handling the components with clean gloves • Keeping everything organized for cleaning and r
Vineta Mills
3 hours ago1 min read


How to Update Retention Times After Clipping a GC Column | Agilent EnviroQuant GC/MS
Clipping a GC column can shift retention times — but your GC/MS calculation method still contains the old values. In this video, I show how I update retention times in Agilent EnviroQuant after trimming a GC/MS capillary column. I walk through the actual software workflow: • Review the chromatogram after the column has been clipped • Check the new compound retention times • Load the appropriate quantitation/calculation method • Confirm compound identification • Open the calib
Vineta Mills
4 hours ago1 min read


How to Replace a Capillary Column in an Agilent GC/MS | Inlet & MSD Installation Step-by-Step
How to replace a capillary GC column in an Agilent GC/MS. In this hands-on video, I walk through capillary column installation from the inlet to the MSD transfer line. Topics covered: • Preparing the column for installation • Making a clean, square column cut • Installing the correct nut and ferrule • Setting the correct column insertion depth at the inlet • Installing the column into the MSD transfer line • Avoiding leaks and poor positioning • Checking the installation befo
Vineta Mills
4 hours ago1 min read


How to replace a Capillary Column in an Agilent GC/MS | Inlet & MSD Installation Step-by-Step
How to replace a capillary GC column in an Agilent GC/MS. In this hands-on video, I walk through capillary column installation from the inlet to the MSD transfer line. Topics covered: • Preparing the column for installation • Making a clean, square column cut • Installing the correct nut and ferrule • Setting the correct column insertion depth at the inlet • Installing the column into the MSD transfer line • Avoiding leaks and poor positioning • Checking the installation befo
Vineta Mills
Sep 171 min read